Kurita water treatment chemicals & Xylem side stream filters Treated right. Filtered clean.
Authorized distributor of Kurita chemicals and of Xylem side stream filtration for Southeast Asia.
Request a quotation Message on WhatsApp Countries supplied · Malaysia · Singapore · Thailand · Indonesia · Vietnam · Philippines Authorized Kurita distributor
Malaysia · Kurita Japan · Kurita Europe
Authorized Xylem distributor
Southeast Asia
01 — Side stream filtration · Xylem
Side Stream Filtration Supply Suspended solids in cooling towers cause fouling, under-deposit corrosion and microbial growth and they reduce chiller efficiency. Filtering 5–10% of the recirculation flow keeps the system clean.
Side stream filter on a cooling tower loop What side stream filtration prevents 01
Fouling
Dust, silt and debris settle in condenser tubes and fill packs, cutting heat transfer.
02
Under-deposit corrosion
Sludge holds stagnant water against metal surfaces, where corrosion runs unchecked by inhibitors.
03
Microbial growth
Solids shelter bacteria and biofilm (including Legionella) and use up biocide.
04
Lower chiller efficiency
Fouled condensers raise approach temperature, so chillers draw more power for the same load.
Design basis · 5–10% of recirculation flow · returned to basin
Evoqua VAF™ V-Series · now part of Xylem
Automatic self-cleaning screen filter: VAF™ V-Series Inlet · outlet
Screen · 10–1500 µm
Body · glass-reinforced nylon
Flush · 10–15 s
Screen filter · 7–50 m³/h
VAF™ V-200 self-cleaning screen filter The V-200P flushes itself automatically in 10–15 s when differential pressure reaches 0.5 bar, using about 15 L per flush and stays online throughout. Its water motor drive needs no electrical power for cleaning.
Flow 7–50 m³/h per filter (varies with micron) Nominal 30 · 36 · 44 · 50 m³/h at 50 · 80 · 100 · 120+ µm Screens 10–1500 micron, 316L SS sintered weave-wire Flush Automatic, 10–15 s at 0.5 bar ΔP · 15 L per flush Online Stays in service while flushing Power None: water motor drive runs on line pressure Pressure 2–8 bar · max 40 °C Body Glass-reinforced nylon · 3″ BSP/NPT/grooved inlet/outlet · 1.5″ flush outlet Control MicroFlush™ controller, up to four filters Size a V-200 for my tower Data sheet · PDF ↓ Screen
Suction scanner
Flanged connections
Screen filter · larger flows
VAF™ V-1000 self-cleaning screen filter The V-1000 handles 14–374 m³/h per filter in a 316L stainless steel body. It flushes automatically in 12–15 s when differential pressure reaches 0.5 bar, using about 57 L per flush and stays online throughout.
Flow 14–374 m³/h per filter (varies with micron) Nominal 242 · 325 · 356 m³/h at 100 · 200 · 300 µm Screens 10–1500 micron, 316L SS sintered Flush Automatic, 12–15 s at 0.5 bar ΔP · 57 L per flush Online Stays in service while flushing Pressure 2–10 bar · max 80 °C Body 316L SS · 6″ or 8″ inlet/outlet · AWWA Class D flanges Control MicroFlush™ controller, up to four filters Ask about the V-1000 Data sheet · PDF ↓ Particle size
How fine each filter goes Typical particles
Bacteria
Silt · clay
Sand · grit · debris
Sand filter
≈ 10–20 µm · indicative
VAF™ screen filter
10–1500 µm screens
0.1 µm
1
10
100
1000+ µm
Smallest particle removed, log scale. Bars show the range each filter type captures. Comparison
Which filter fits my system? VAF™ V-200 VAF™ V-1000 Flow range 7–50 m³/h per filter 14–374 m³/h per filter Micron rating 10–1500 micron, 316L SS sintered screens 10–1500 micron, 316L SS sintered screens Footprint Compact inline · 3″ inlet/outlet · 1.5″ flush outlet 164.6 cm long · 6″ or 8″ flanged inlet/outlet Power need None: runs on line pressure MicroFlush™ controller, up to four filters Typical application Cooling towers and closed loops, small to mid recirculation flows Larger cooling tower and process flows
02 — Kurita water treatment chemicals
World-class chemistry, Now on your site Oasis supplies Kurita chemistry for cooling, chilled water, boiler and membrane systems and sets up the dosing and monthly testing to go with it.
Kurita
Corrosion & scale inhibitors Inhibitor programmes that protect heat-exchange surfaces and pipework from scale and corrosion.
Cooling towers · Chilled water · Closed loops
Kurita
Cooling tower biocides: oxidising and non-oxidising, Legionella control Biocide programmes that control slime, algae and Legionella, dosed on a schedule and verified by testing.
Cooling towers · Basins · Fill packs
Kurita
Chlorine & chlorine-based solutions Chlorine-based disinfection for cooling water and make-up water.
Cooling towers · Make-up water
Kurita
Boiler water treatment chemicals Treatment for steam and hot water boilers to control scale, corrosion and carryover.
Steam boilers · Hot water boilers · Condensate
Kurita
Dispersants, deposit control and cleaning/descaling chemicals Keeps suspended matter moving and removes existing deposits during system and chiller tube cleans.
Cooling towers · Chillers · Heat exchangers
Kurita
RO / membrane chemicals Antiscalants, cleaners and biocides for reverse osmosis and membrane systems.
RO plants · UF / membranes
Any chemical in the Kurita portfolio can be sourced and supplied through Oasis. Ask us.
Ask about a Kurita product 03 — FAQ
Questions buyers ask us. Who is the Kurita distributor in Malaysia? Oasis Engineering & Supplies Sdn Bhd is an authorized distributor of Kurita water treatment chemicals in Malaysia, supplying products from Kurita Japan and Kurita Europe. Oasis has offices in Penang and Selangor and serves 257+ active accounts across Malaysia.
Where can I buy cooling tower biocide in Malaysia? Oasis supplies oxidising and non-oxidising cooling tower biocides from the Kurita range, including programmes for Legionella control, across Malaysia from its Penang and Selangor offices. Oasis can also install the dosing system and test the water monthly.
What is side stream filtration for a cooling tower? Side stream filtration takes a portion of a cooling tower’s recirculating water, typically 5–10% of the flow, passes it through a filter to remove suspended solids and returns it to the basin. This reduces fouling, under-deposit corrosion and microbial growth and helps keep chiller efficiency up.
How much side stream filtration flow do I need? A common design basis is 5–10% of the recirculation flow rate. A system recirculating 500 m³/h would typically need 25–50 m³/h of side stream filtration. Dust load, basin design and water quality affect the final size; send Oasis your flow rate and we will size it.
What’s the difference between a screen filter and a sand filter? A screen filter traps particles on a mesh screen, rated from 10 to 1500 micron on the VAF V-Series and cleans itself with a short automatic flush. A sand filter traps particles in a bed of media and is backwashed periodically.
Do you supply Xylem / Evoqua VAF filters in Malaysia? Yes. Oasis is the authorized Xylem distributor for Southeast Asia for side stream filtration, including Evoqua VAF™ V-Series self-cleaning screen filters such as the V-200 and V-1000. Oasis supplies and services them in Malaysia.
04 — Request a quote
Tell us about your system. Send your system type and recirculation flow rate and an Oasis engineer will come back with a chemical programme, a filter size or both.
Message on WhatsApp HQ
Penang
354-H, Jalan Jelutong, Jelutong, 11600 Jelutong, Pulau Pinang
04-281 2648 Office
Selangor
No. 48, Jalan Bulan U5/167, Seksyen U5, Bandar Pinggiran Subang (Subang 2), 40150 Shah Alam, Selangor
03-7859 7648 Email
General enquiries
Services across Malaysia. Filtration distributorship across Southeast Asia.
info@oasis-eng.com.my System type
What you need
Next: your phone and email, so an engineer can reply